Optimisation of Embryonic and Larval ECG Measurement in Zebrafish for Quantifying the Effect of QT Prolonging Drugs

Authors
Dhillon, S.S., Doro, E., Magyary, I., Egginton, S., Sik, A., and Muller, F.
Source
Full text @ PLoS One

Investigation of effect of electrode position on ECG waveform.

A) Mean ECG interval measurements obtained from 3 dpf larvae at different electrode positions over the heart (n = 10 per position), B) diagram of a 3 dpf larva with numbers identifying the different measurement positions; image created using Adobe Photoshop CS6, C) 1) 2 second raw ECG recording and 2) 2 second raw ECG recording from a 5 dpf larva after moving positive electrode 10 μm forward longitudinally, D) comparison of QTc intervals measured from 5 dpf larvae (n = 3) at starting position (atrium/ventricle boundary) and after movement of electrode longitudinally by 5 μm and 10 μm. Key: 1 = sinus venosus, 2 = between atrium and sinus venosus, 3 = base of atrium, 4 = apex of atrium, 5 = between atrium and ventricle, 6 = base of ventricle, 7 = apex of ventricle and 8 = bulbus arteriosus.

Electrode positioning for ECG recording. Depiction of a 2 μM electrode tip positioned on the heart of a 60 hpf zebrafish embryo to illustrate the relative sizes.